What is a tower UPS battery? Features and installation methods of power frequency tower UPS batteries

Avtor: Iflowpower – Dobavitelj prenosnih elektrarn

What is the characteristics and installation method of tower UPS? Power frequency tower UPS. Tower UPS is a high-performance sine wave uninterruptible power supply designed for data centers, network computer rooms, smart precision equipment, and complex industrial environments. Its high reliability is financial, communications, insurance, transportation, tax, military, securities, Energy, education, governments, manufacturing, company and other industries supply important power supply.

Xiaobian gives you what is the characteristics and installation method of tower UPS? Power frequency tower UPS. What is a tower UPS? Tower UPS is a server structure type UPS because its shape and structure are very similar to the vertical PC. Because the main board of the server is strong, the slot is also a bunch of slots, so the head is larger than the ordinary motherboard.

Tower UPS host chassis is larger than standard ATX chassis, because it is generally necessary to reserve enough internal space for redundant expansion of hard drives and power supplies in the future. In the field of application, the Tower UPS is important to be applied in the data room. Placed on the ground, the UPS on the table is the tower machine UPS.

You cannot add the guide rail, you cannot put it on the rack! When the normal AC power is interrupted, the DC transformation of the battery output into a power supply device for continuously powering. Important to supply uninterrupted power supply to a single computer, computer network system or other power electronic devices. Make the load to maintain normal operation and protect the load soft, the hardware is not damaged, making the equipment working properly; the data being processed is not lost.

Tower UPS Features Tower UPS Important Application In China Large Data Center, Dispatch Center, Control Center, Management Center, etc. It has high reliability, high efficiency, high power density, using full digital control and IGBT rectifier technology, through more than 1400 tests, ensuring excellent output quality under any working conditions. Efficiency can reach 95% in 20% load, 40% load can reach 96%, more matching data center real business scene, help customers reduce energy consumption of more than 50%, save electricity spending.

With remote dry interface and RS232 monitoring interface: normal work, unusual market, battery low pressure gauge, equipment failure. Characteristics of Power Frequency Tower UPS ● Green Power Design, Energy Saving Environmental Protection ● Ultra Wide Input Voltage Frequency Rate, Adapts to the most demanding power environment ● Mature digital control technology, strong power semiconductor device, triple hardware and hardware protection, more secure and reliable ● Output power factors can be up to 0.9, supply more energy ● High efficiency electrical design, efficiency in online mode is as high as 90%, saving operational costs, reducing more emissions ● Green environmental protection, complying with EU environmental protection instructions ● Intelligent human design , Flexible expansion ● Battery is easy to configure, can meet different discharge time requirements ● Smart real-time battery monitoring, battery status is in the installation method of the power frequency tower UPS 1, packaging check open packaging, package should be: UPS machine and manual.

Odstranite UPS, preverite, ali je stroj med transportom poškodovan. Če pride do kakršnih koli poškodb ali pomanjkanja delov, ga ne zaganjajte in obvestite prevoznika ali distributerja. 2.

Priključitev baterije za priključitev baterije na hrbtno ploščo na hrbtno ploščo na pozitivno elektrodo baterije, črna črta povezave baterije je povezana z negativno elektrodo baterije. 3, Občinska električna povezava Ko vhodni napajalni kabel poveže napravo UPS in električno omrežje, začnite polniti baterijo. Priporočljivo je, da se stroj polni 6 ur.

4. Priključna naprava povezuje vhodni napajalni kabel naprave z regulirano izhodno vtičnico baterije na hrbtni plošči UPS-a. Opomnik: Prosimo, potrdite, da je UPS vklopljen, da zagotovite, da lahko UPS zaščiti podatke iz povezane pomembne opreme, ko je mesto izklopljeno.

Opomba: tiskalnika ali optičnega bralnika ne priključite na izhodno vtičnico za baterijo regulatorja UPS, kar bo močno povzročilo, da UPS zaradi preobremenitve ne bo deloval pravilno. 5. When turning on the UPS to turn on the UPS machine, tap the switch button, the indicator lights up.

UPS ima funkcijo neposrednega pretoka, ne zaženite UPS neposredno, enostaven za uporabo. Ko je mesto prekinjeno, se UPS prenese na rezervno napajanje, pravočasno plačajte shranjevanje ali drugo nujno zdravljenje izklopa za osebni računalnik. Ko si trg opomore, pravočasno vklopite UPS, da napolnite baterijo.

6. Ko izklapljate UPS Zaprite UPS stroj, ponovno pritisnite gumb stikala, prižge lučka. The important use of the UPS is that in the power outage, the unit supply continuously powers, thereby ensuring the computer network system, other application systems run, effectively prevent data loss.

Before the use of the power supply, specifically understand the Tower UPS and its installation methods, which are concerned about the concern.

Babak sareng kami
artikel anu disarankeun
Pangaweruh Warta Ngeunaan Tatasurya
euweuh data

iFlowPower is a leading manufacturer of renewable energy.

Contact Us
Floor 13, West Tower of Guomei Smart City, No.33 Juxin Street, Haizhu district, Guangzhou China 

Tel: +86 18988945661
WhatsApp/Messenger: +86 18988945661
Copyright © 2025 iFlowpower - Guangdong iFlowpower Technology Co., Ltd.
Customer service
detect