loading

  +86 18988945661             contact@iflowpower.com            +86 18988945661

How to repair colloidal batteries

著者:Iflowpower – Lieferant von tragbaren Kraftwerken

1), charging method: Generally, the battery is lighter, can recover normal charging. Generally, the larger the discharge current, the shorter the battery life; the deeper the discharge depth, the shorter the life of the battery. From the theory, the battery should be made deep and discharged, and the shallow charge should be made.

Colloidal battery (2), hydrotherapy: a heavy battery, hydraulic charge and discharge. 1) Dissolving pure concentrated sulfate of 1.050 with a density of 1.

050 with a dilute sulfate solution of 1.050 with a 500 ml drip bottle capacity of a hospital. 2) Open the battery cover (not to be careful to avoid damage), rotate the monobath control valve (or pick the rubber cover), add 5 ml of the electricity of 1.

050 electrolyte 5 ml to 15 ml, after injection of the electrolyte Preferably, the battery is placed for 10 hours, so that the supplementation liquid is soaked into the separator to just see the flow electrolyte appear (more clearly in the vertical image of the handle) or the battery is flipped 90 degrees, so that the small hole is facing On the side, the excess electrolyte overflows, then fell back). 3) Connect the battery and probe, press the detector battery repair function button to repair. The detector automatically enters three six-hour debris repair.

After three hours of sulfur time, automatically transfer to the working mode 3, both charging discharge charge, charging current is 3A, the discharge current is 5A, the detector automatically displays the discharge capacity and time, very intuitive. Each record, repeated three, four times until the capacity is no longer rising. (3), battery side-by-side discharge method: / 2 (ignore internal resistance difference), the effect is also very good.

(4), battery series repair method: This method is used when the single battery nominal voltage is below 12V. For example, on the market, charging emergency lights often use 6V4AH, as well as 6V7AH battery, and the detector single-channel output is 12V. (5) Output joint charge increase method: If the battery capacity is large, if some cars are 100AH ​​batteries, sometimes new charge currents, at which time the two or more outputs of the detector can be used in parallel.

To the repaired battery to enhance charging current. .

Harremanetan jarri gurekin
Gomendatutako artikuluak
Ezagutza Berriak Eguzki Sistemari buruz
Ez dago daturik

iFlowPower is a leading manufacturer of renewable energy.

Contact Us
Floor 13, West Tower of Guomei Smart City, No.33 Juxin Street, Haizhu district, Guangzhou China 

Tel: +86 18988945661
WhatsApp/Messenger: +86 18988945661
Copyright © 2025 iFlowpower - Guangdong iFlowpower Technology Co., Ltd.
Customer service
detect