UPS battery is simple installation, but also pay attention to some problems, after installation, pay attention to some matter. Text: UPS is called uninterruptible battery because it can quickly convert it to the inverter state, so that the computer is not allowed to lose important documents because of sudden power outages in the future. Not used as a spare power, if you just want to use electricity while powering up, it is enough to buy inverter.

Most of the general home UPS is the maintenance-free lead-acid battery. The UPS battery is a device used as a storage electrical energy. It is connected in series by several batteries, and its capacity size determines its maintenance discharge (power) time.

Ordinary backup, online interactive or backup / ferromagnetic UPS does not have a ripple current, and other designed UPS will have a ripple current of size, depending on the specific design method. As long as you check the configuration chart of the UPS, you can understand whether the UPS can appear ripple current. If the online UPS battery is between the charger and the inverter, the battery will have a ripple current, which is a normal dual-transform UPS.

If the battery is separated from the inverter with a cutoff diode, the relay, the transducer, or the rectifier is separated, then the UPS battery does not have a ripple current. Of course, this design is not always online, so this UPS is called a mixed backup / online UPS. The battery is the least reliable part in the UPS system, but the UPS design is good and bad directly affects the reliability of the battery.

Let the UPS battery keep the state of charge (even if the UPS stop) can extend the battery life, try to prevent the use of battery voltage high-powered UPS. Some UPS design will cause the battery to have a ripple current, resulting in unnecessary overheat of the battery. Most ups used by the battery are similar, but the UPS design will greatly affect the life of the battery.

Be sure to follow the following: Do not install the UPS battery near sealed space or fire, otherwise there is a danger of trigger explosion and fire; do not use ethylene film to cause static things to cover up UPS batteries, sometimes static electricity It will cause an explosion; do not install the UPS battery in places that may be in water, otherwise there is an electric shock, fire; please do not install the UPS battery in the -40C ~ 60C environment; do not use the battery in places with dust, otherwise It may cause a UPS battery short circuit; when the battery is placed in the box, pay attention to the air flow; do not have a sticky or label object to press the upper cover, because there is an exhaust valve under the upper cover, the gas that appears in the battery will not be Out; When the number of parallel is floating, the plug-in terminal battery can only be associated with three columns, and the bolt fastening terminal is not particularly limited, but the inclusion of the parallel number of small reliability has increased. In addition, when connected to the line, it is necessary to consider that the wiring conductor and contact resistance between the columns are equivalent, in order to keep each column charge and discharge battery balance, please do not exceed three columns in actual use. The UPS battery is an important part of the entire UPS power supply.

Once the UPS battery is stopped, the entire UPS power supply cannot work properly, so we should pay attention to the use of the UPS battery during the UPS power supply. Summarize the following points for the use of the UPS batteries: 1. Confirm that the use conditions meet the manufacturer's specifications.

2, use the first use or long-term placement Be sure to charge. 3, the battery used by the UPS is used for floating use, if used frequently using the battery (similar to cyclic use), will seriously affect the vehicle's trickle life. 4, regular battery check.

5, if the electric trough deformation and leakage are found, please do not use, should be replaced. 6, the terminal is in place, if the connection is not tight, there is a risk of fire. 7.

It is recommended that it can be discharged from 3 to June. If there is an abnormality such as the charging voltage or discharge characteristics of the battery, please replace this battery. 8.

When the battery capacity is below 50% of the initial capacity, the battery should be replaced in time.

GET IN TOUCH WITH Us
recommended articles
Knowledge News About Solar System
no data

iFlowPower is a leading manufacturer of renewable energy.

Contact Us
Floor 13, West Tower of Guomei Smart City, No.33 Juxin Street, Haizhu district, Guangzhou China 

Tel: +86 18988945661
WhatsApp/Messenger: +86 18988945661
Copyright © 2024 iFlowpower - Guangdong iFlowpower Technology Co., Ltd.
Customer service
detect