Author :Iflowpower – Portable Power Station Supplier
What is the reason for the deformation of the UPS power storage battery? The UPS power storage battery has a drum-clad deformation. It is important that the battery drum bag is also one of the reasons for battery failure. UPS power storage battery deformation drum phenomenon causes the battery deformation is not burst, often has a process.
What is the reason for the deformation of the UPS power storage battery? The UPS power storage battery is long, and sometimes the drum package deformation is present, in fact, no matter what type of battery, including the mobile phone battery we use, will also have a drum phenomenon. Drum bag affects the battery, and even cause explosion danger. The UPS power battery has a drum deformation.
It is important to have an increase in pressure in vivo. Important reasons have the following points: (1) Sealing battery charging operation, especially in series UPS power storage battery pack, if the battery pack is over Charging, if there is a good quality battery, there is a phenomenon of internal gas composites, thus the puppiness. (2) Safety valve opening valve pressure is too high, or the safety valve is blocked.
When the pressure in vivo increases to a certain extent, the valve cannot be opened normally, and it is bound to deform in this case. (3) Because the sealing battery is a poor solution design, there is a reserved protection against the gas, and if there is a "rich liquid" phenomenon, it will block the O2 spread to the negative electrode, reduce the composite rate of O2, in vivo pressure Increase. (4) The floating voltage is too high, the charging current is large, causing the o2 in the positive electrode plate to accelerate, and it is not as follows to the negative composite, and the temperature rise in the UPS power supply battery is also very fast, in the exhaust, the pressure reaches a press , Make the battery have drum deformation.
The reason for the UPS power storage battery has the following cases: 1, the vent hole clogging or uncomfortable on the battery pack cover or not in the charging process, especially during charging, there will be a large number of explosive gases. If the vent hole is blocked or not smooth at this time, these gases cannot be discharged in time, thereby accumulating in the battery case, the pressure is getting bigger and larger, and finally put the battery tumbles. 2, the battery polar plate is vulcanized.
During the charging battery of the polar plate, the temperature of the single voltage and the electrolyte will rise rapidly during the charging of the large current, and the bubbles have become early and severe, and it is easy to cause battery drums. From the above-mentioned reason why the UPS power storage battery has occurred, it is necessary to prevent the battery's cracking accident. First, it is necessary to prevent sparks in the battery of the battery, which will be firmly installed in the process of use.
The connection of the wire connector and the electric pile is fastened. When charging the battery, be sure to prevent the current from excessively or overcharge. To this end, it is necessary to adjust the rated voltage of the generator; for the battery of the charging, it is necessary to grasp the charging current and charging time.
Summary: In the process we use, if you find that the UPS power battery has drum phenomenon, you should replace the UPS battery of the drum, so as not to affect the use of other batteries, or affect the use of the entire device.