Author :Iflowpower – Portable Power Station Supplier
Rack UPS installation considerations, can not save your life. Installing the rack UPS should take into account the power grid situation, use the environment, grounding situation, power distribution requirements, etc. These problems are not htger, because the one is a problem, the consequences are unbearable.
Therefore, Xiaobian will come to explain with you how to install rack UPS, and some of our questions we have to pay. First of all, let's take a look at what rack-type UPS? Rack UPS is an important application of power supply equipment for security system integration centralized power supply, which is an inevitable product for standardized management and centralized management of security systems. Can be sine wave output, zero conversion time.
Rack UPS is more saved more than traditional UPS, and the appearance is like a rack server. Rack type UPS size, supercapable, high efficiency. Save floor area, easy to install, use and maintain; shorter power connection cables, high reliability.
Rack UPS installation notes: 1, use environment: temperature: 0 ¡ã C - 40 ¡ã C; humidity: 10% - 90%; can not be placed in humid, dirty, no air convection, surrounding environment Clean, this can reduce the corrosion of harmful dust on the internal line of rack UPS. 2, power distribution requirements: About the input, output wiring of the machine, the user's electrician should be in advance and pull it to the installed site machine placement point to reserve a certain length (generally reserved 1-1.5m long) so that the machine is successfully installed.
3, the access line diameter selection: machine input, output line diameter selection, can not be lower than the national electricity safety standard, special attention: about the three-in-line machine, its bypass fire line and the neutral line of the line must be Three times the other two-phase fire line! 4, output prevention: When the user wiring, the output must be drawn separately! Set the output dedicated plug / socket must be strictly distinguished from the daily electrical plug / socket, and to mark the marked identification. The output plugging of the machine, the socket should not be placed with ordinary insert sockets or stacked! To prevent accidental, the machine is inserted into the decoration electric drill, the vacuum cleaner and other power equipment damage the rack UPS power supply. 5, safe grounding: Check the grounding ground line, whether the ground resistance is based on national standards, which is beneficial to machine safety operation and lightning protection.
6, system test, rack UPS power supply rectifier device, inverter device and static switching device specifications, models meet design requirements. The internal knot is connected correctly, the fasteners are complete, reliable without loose, welding connection without falling off. 7, do not try to repair the rack-type UPS power supply, the UPS power supply does not contain parts that may maintain, and the rack-type UPS power supply contains potential hazardous voltages, and the maintenance can only be carried out by the manufacturer training.
8. Regularly check that the battery pack prevents the battery damage caused more losses! Ok, Xiaobian is temporarily shared here. In short, the mounting rack type UPS must be installed by professional technicians to install it, and cannot be repaired or modified.
Rack UPS products have won unanimous praise from various industries with its stable performance and excellent technology, service is also a lever! There is a pro, you can consult our customer service onlin.