How to maintain the rack UPS can you make it longer in the room cabinet?

  Author :Iflowpower – Portable Power Station Supplier

How to maintain rack-type UPS can allow it to have a longer life in the machine room cabinet? Rack UPS is designed for new generation of smart data centers, widely used in distributed machine rooms, load-bearing limited machine rooms, stages deployment machine rooms , Quick deployment of computer rooms and integrated cabinets and other power supply applications. So, how long does it take to use life? How to maintain the rack UPS power supply extension? Normally, the service life of the rack UPS power supply can generally reach 8-10 years, but maintenance proper UPS power supply This can be used for more than 15 years. The battery has a period of regular maintenance, battery and UPS.

It can be used for more than 15 years. It has been used for more than 20 years, and the UPS power supply is also never. No change.

The following small series will introduce the maintenance of the rack UPS power supply and how to extend the rack UPS power life? Moisture-proof, sun protection. 2, the input voltage is within the design range, the most reasonable range of load is 30% -60%, full load, overload use can affect the life of the UPS, at least once a year. 3.

Maintain a suitable ambient temperature: Important factors affecting battery life are environmental temperature, the best ambient temperature required by general battery manufacturers is between 20-25 ° C. The temperature is too high or too low, will speed up the life of the battery. 4, using communication function: Most large, medium-sized rack UPS has operational performance with micro-machine communication and program control.

Through the information query, you can get information such as the mains input voltage, UPS output voltage, load utilization, battery capacity utilization, temperature and city-speed frequency, and make it easy to use the rack UPS power supply and its battery. 5, regular charging discharge: generally discharge every 2-3 months, the discharge time can be determined according to the capacity of the battery and the load size. After the full load is complete, it will charge more than 8 hours according to the regulations.

6, timely replacement waste / bad battery: When a certain / other battery in the battery pack is damaged, the maintenance personnel should check each battery to exclude damaged batteries. When replacing new batteries, you should strive to purchase a battery with a model of the same model, prohibiting an anti-acid battery and a sealed battery, a battery of different specifications. Extended tips for rack-type UPS power life.

▲ Prevent overloads from using the rack-type UPS power supply, and calculate the size of the load when using the UPS power supply, to prevent excessive or too small loads, excessive loads will make the UPS power supply in overload status to shorten the UPS The service life of the power supply. ▲ Use of AC regulator: After using the rack UPS power supply, no additional AC regulator. If necessary, it should be added to the predecessor of the UPS power supply, that is, the city electricity is the AC regulator, then the UPS power supply, then to the load.

▲ Using the rack-type UPS power supply boot and shutdown sequence: The correct boot button should be to open the UPS power supply to power it, then open each load, which prevents the current shock from the moment from starting to damage the UPS. The order in the shutdown is just the opposite should turn off each load to close the UPS. ▲ UPS power supply is not long-term idle: Excessive discharge and battery long-term opening of the battery need to increase the internal resistance of the battery, can be charged, discharge performance deteriorate.

Regarding the rack-type UPS power supply that has long idle, let the charging circuit in the UPS power supply in 12 hours before 12 hours before rebooting. Characteristics of lithium-ion battery UPS: · Lithium electrical properties, lithium-ion battery pack recirculation times reached more than 2,000 times, service life is 10 years; · Rapid deployment; 19-inch standard rack type, easy installation, easy deployment, easy maintenance · Many outputs, compatible with multiple ways, 110/220/380 VAC, 12/24/48 VDC; · Embedding installation, the system can be embedded in the load device to meet customer customization requirements; N + X Central Reduction Degree, Meeting User Post Expansion; · Efficient Energy Saving, ECO Operation Mode, Efficient Energy Saving, Reduces User Cost; · Automatic Identification, Adapt to 50Hz / 60Hz Power System to meet global power system requirements; · Many Monitor, support RS232 / 485, supply users to users, multi-level monitoring management. .

GET IN TOUCH WITH Us
recommended articles
Knowledge News About Solar System
no data

iFlowPower is a leading manufacturer of renewable energy.

Contact Us
Floor 13, West Tower of Guomei Smart City, No.33 Juxin Street, Haizhu district, Guangzhou China 

Tel: +86 18988945661
WhatsApp/Messenger: +86 18988945661
Copyright © 2025 iFlowpower - Guangdong iFlowpower Technology Co., Ltd.
Customer service
detect