UPS power storage battery assembly suggestion, how does the UPS battery maintenance? UPS battery is used as the backup energy of the UPS power system is also an important part of the UPS power system, especially the large number of large and medium-sized UPS power cells, large capacity, weight, if the installation is unreasonable, cause damage to the building, Problems with casualties, post-maintenance difficulties and unable detection, etc. This article talks about the UPS power storage battery assembly recommendation and how the UPS battery is maintained? UPS power storage battery assembly recommendation 1. Equipment in place, unpacking inspection equipment during transportation, there is no bump, appearance is damaged, and the battery has no inverted phenomenon.
2 : (1) DC does not check the battery connection with the battery connection; (2) No abnormality for the next installation step. 3. Connect the battery pack with the UPS power supply, the main electricity input output is connected, turn on the back of the UPS power supply, the external table detects the voltage, no abnormal boot debugging.
UPS battery maintenance, try to prevent battery overvoltage, overcurrent charging overvoltage charging tends to cause water contained in the battery electrolyte to hydrogen and oxygen, thereby shortening the UPS battery life; overcurrent charging It is easy to cause the positive and negative plates of the battery to make the active substance of the surface of the plate surface, resulting in a decrease in the battery available, which will cause the internal polar plate short circuit to be short-circuited. Second, the battery replaces the decline in the degradation of the UPS power battery use time, the charge and discharge characteristics of some batteries will gradually deteriorate, the end voltage is significantly decreased, and the performance of this battery is impossible to rely on the UPS power supply. The internal charging circuit is solved, there will be hidden dangers in continuing use, and should be replaced in time.
Third, prevent the new and old battery mixing due to the internal resistance of the new UPS battery, while the internal resistance of the old battery has different degrees, when the old old battery is mixed together, due to the internal resistance of the old battery, partial pressure It will be relatively large, and it is easy to cause overvoltage charging; regarding new batteries, the internal resistance is small, the charging voltage is small but the current is large, and it is easy to cause overcurrent phenomena, so the new old battery can be prevented during charge and discharge. Fourth, the use of the battery of the battery is closely related to the ambient temperature of the UPS power storage. When the battery is at a lower temperature, the zinc plate in the battery is easily powdered, loss of electric storage performance, causing longness damage; when the temperature is too high, the battery is too high The capacity will also fall, and the situation will cause longness damage when it is serious.
According to the technical specifications of the UPS battery manufacturer, the excellent use temperature of the battery is 2 ~ 25 ¡ã C, which can extend the battery life in this temperature range. In fact, problems caused by the lack of maintenance of the battery are quite high in all faults in UPS. Therefore, the UPS power storage battery will be routinely maintained, which will greatly extend the battery life of UPS and reduce the fault rate.