loading

  +86 18988945661             contact@iflowpower.com            +86 18988945661

How to maintain maintenance lead-acid batteries?

  Author :Iflowpower – Portable Power Station Supplier

Maintenance of lead-acid batteries To allow battery-maintaining good performance and extending its life, and floating storage batteries should be regularly charged and discharged per month. The performance of the battery performance and the long service life are large depending on the usual maintenance. Battery should be inspected regularly (clean, measured, supplement distilled water, charge and discharge.

). 1) The electrolyte density used in the battery should be between 1.260-1.

280, the temperature high, can take the lower limit density value, and the low temperature is low. 2) The battery after discharge should be supplemented in time, and must not put it for more than 12 hours. 3) The battery-connected battery should be the same model, and the degree of discharge between each other must not exceed 15%.

4) The battery temperature should not be too high during charging, and measures should be taken to cool down. 5) The battery should pay attention to the degree of discharge, prohibit over-discharge, in general, the amount of discharge must not exceed 50% of the rated capacity, the determination of the degree of discharge can be determined by the electrolytic solution density, and the electrolyte density is reduced by 1%, and the capacity is reduced. 6%.

6) The liquid level height and density of the electrolyte should be often checked, and the adjustment should be adjusted; due to the reduction of the liquid level of the water, the residual water is adjusted; since the electrolyte spindle is lowered, the same sulfuric acid solution as the electrolyte density can be injected. ; In general, distilled water can still be adjusted. 7) The battery and the surrounding should remain clean and no debris, often cleaning the exhaust gas mixing hole, wipe the surface dust and dirt with dry cloth.

8) Prevention of metal equipment shorts the electrode column to avoid accidental casualties. 9) There should be a good ventilation equipment in the charging room, which is strictly prohibited to smoke or open fire operations in charging indoor. 10) Preventing 入 入 入 入 杂 杂 杂.

.

GET IN TOUCH WITH Us
recommended articles
Knowledge News About Solar System
no data

iFlowPower is a leading manufacturer of renewable energy.

Contact Us
Floor 13, West Tower of Guomei Smart City, No.33 Juxin Street, Haizhu district, Guangzhou China 

Tel: +86 18988945661
WhatsApp/Messenger: +86 18988945661
Copyright © 2024 iFlowpower - Guangong iFlowpower Technology Co., Ltd. | Sitemap
Customer service
detect