Description Method for reducing UPS power battery failure

2022/04/08

  Author :Iflowpower – Portable Power Station Supplier

How much fault occurs when the UPS power supply is used for a long time, and the statistics of UPS maintenance work. Reserve UPS power supply is 50% due to battery triggers. Online UPS power supply is reasonable for designing circuitry, the balance taken by the drive power component capacity, so the power supply circuit is very low, and there is a battery failure rate of 60%.

Therefore, the correct use of maintaining the life of the UPS battery is one of the key factors that reduce the failure of uninterruptible power supply. Method 1 of reducing UPS power battery failure 1. Regularly check the end voltage and internal resistance of each unit battery periodically.

For 12V unit cells, if the end voltage between each unit battery is found to exceed 0.4V or more than 80MΩ or more, the unit cell should be balanced to restore the battery within the battery. Resistance and eliminating the end voltage between each unit battery.

The charging voltage takes 13.5 ~ 13.8V when charging.

Most batteries that have a good balance charging process can restore their internal resistance to 30MΩ. During operation, the UPS power supply is eliminated due to the above-described imbalance of each unit battery characteristics, which is impossible to rely on the charging circuit inside the UPS power supply, so that this characteristic has a significantly unbearable battery. Group, if the offline is not charged in time, its unevenness will become more and more serious.

2. Re-floating the UPS power downtime for more than 10 days, before rebooting, the UPS power supply should be started under the conditions that do not load the load to re-use the charger product electrical circuit to re-carry the battery to the battery 10 to 12h. run.

The UPS power supply is in a floating state without the discharge process, which is equivalent to the state of "storage.". If this state is too long, the battery has not been scrapped due to "long-term storage", which is mainly manifested as the increase in battery internal resistance, and the internal resistance can reach a few Ω.

We found that after 2 months of room temperature, the battery can be used for about 97% of its rated value. If the storage is 6 months, its use capacity becomes 80% of the rated capacity. If the storage temperature rises, its use capacity will decrease.

It is therefore recommended that the user is best to unplug the mains input every 20 ° C, so that the UPS power supply is operated by the battery to provide energy to the inverter. However, this operation should not be too long, and about 30% of the load is about 30% of the rated output, it can be discharged. How to reduce the failure of the UPS power battery 3.

Reduce the service life of deep discharge electricity is closely related to the depth of it is discharged. The lighter the load of the UPS power supply, the larger the amount of capacity of the electric storage and its rated capacity, the ratio of the ratio of the power storage is, in which case the battery is automatically shut down when the battery voltage is too low due to the low battery voltage The depth of discharge is relatively deep. How does the actual process reduce the battery in depth? Method is simple: When the UPS power supply is in the middle of the electric power supply interruption, most of the UPS power supplies will be around 4s at the gap 4S when the UPS power supply is powered by the electric power supply.

Periodic alarm sound, notifying the user that now is the battery. When he heard the alarm sound is urgent, the power supply is already in depth, and should immediately perform emergency treatment, close the UPS power supply. Not forced, generally don't let the UPS power have been working until the battery voltage is too low and the automatic shutdown ends.

4. Using the high peak charging of the power supply to the UPS power supply for a long time in the market, low-voltage power supply or frequently-stopped power, to prevent the battery from being damaged by the long-term charging, it should be fully utilized to charge the battery to the battery. Ensure that the battery has sufficient charging time after each discharge.

Generally, after the battery is discharged, it is charged to 90% of the rated capacity to at least 10 to 12 h. Note that the charger's selection UPS power supply-free seal battery cannot be charged with a controlled silicon type "fast charger". This is because this charger will cause the battery to be in the harsh charging state of "instantaneous overflow charging" and "instantaneous transient charging.

This state will make the battery greatly decreased, and the battery will be scrapped when it is severe. When using the UPS power supply of the constant voltage cut-off charging circuit, be careful not to adjust the battery voltage too low protection work points, otherwise, it is prone to overflow charging in its initial charging. Of course, it is best to use a charger that has both constant current, and constant pressure.

5. Ensure that the capacity of the power supply ambient temperature battery is closely related to the ambient temperature. In general, the performance parameters of the battery are calibrated at room temperature for 20 ° C, and when the temperature is less than 20 ° C, the power storage capacity will be reduced, while the temperature is higher than 20 ° C, it is available The capacity used will increase slightly.

Different models of different models of different models are different from the degree of temperature. According to statistics, when at -20 ° C, the battery can only reach around 60% of the nominal capacity. The impact of visible temperature cannot be ignored.

.

CONTACT US
Just tell us your requirements, we can do more than you can imagine.
Send your inquiry
Chat with Us

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English